About the effect of expansion of reproduced frequency band by electroacoustic transducer

Authors

  • A. Sharapov
  • M. Мusiyenko
  • Zh. Sotula
  • L. Kunickaya

Keywords:

electroacoustic transducer, sound pressure, electric voltage, meander, spectral density, amplitude – frequency characteristic.

Abstract

The article describes the effect of electroacoustic transducer frequency band expansion. The effect appears when a transducer is affected by electric voltage in the form of meander. A noise meter is used to measure the levels of low-frequency and high-frequency sound pressure produced by electroacoustic transducer under the influence of electric voltage in the form of meander. Based on experiments, the levels low-frequency and high-frequency sound pressure rose by 10-20 dB.

Downloads

Published

2009-09-16

Issue

Section

ULTRASONIC AND ACOUSTIC MEASUREMENTS